赛智科技(杭州)有限公司

主营产品:液相色谱仪,气相色谱仪,离子色谱仪,色谱工作站,色谱配套
产品展示 Products
新闻动态 News
L-8000液相色谱仪梯度自动进样系统
  • 联系人:程志明
  • QQ号码:250504234
  • 电话号码:0571-86631750
  • 手机号码:13858172331
  • Email地址:250504234@qq.com
  • 公司地址:-浙江省杭州市滨江区东冠路611号金盛科技园三号楼六楼
产品介绍.
<h2>L-8000液相色谱仪梯度自动进样系统</h2><p>&nbsp;</p><p><imgsrc="http://user4.dingdanmao.com/Public/Js/Index/Editor33/attached/20230816/20230816015211_98516.jpg"width="800"height="800"alt=""/></p><p></p><p></p><p>二元高压梯度泵:</p><p></p><p>流速范围&nbsp;:&nbsp;0.001&nbsp;mL/min&nbsp;~10.000&nbsp;mL/min&nbsp;(增量&nbsp;0.001mL/min)&nbsp;</p><p>流量准确度:±0.5%&nbsp;(1mL/min,水)</p><p>流量精度&nbsp;:≤0.1%&nbsp;(1mL/min,水)&nbsp;(JJG)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;≤0.07%&nbsp;RSD&nbsp;(1mL/min,水)&nbsp;(ASTM)</p><p>大耐压:</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;9,000&nbsp;PSI&nbsp;(@0&nbsp;~&nbsp;2mL/min)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;6,000&nbsp;PSI&nbsp;(@2&nbsp;~&nbsp;5mL/min)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;3,000&nbsp;PSI&nbsp;(@5&nbsp;~&nbsp;10mL/min)</p><p>压力脉动:&nbsp;≤1%&nbsp;(@1mL/min,水,背压&gt;10Mpa)&nbsp;</p><p>梯度准确度:±0.5%</p><p>梯度重复性:≤0.2%&nbsp;RSD</p><p><imgsrc="http://user4.dingdanmao.com/Public/Js/Index/Editor33/attached/20230816/20230816015258_43849.jpg"alt=""/></p><p></p><p></p><p>自动进样器</p><p></p><p>进样模式:满环进样/部分进样/微升携带进样</p><p>定量环体积:标配&nbsp;100&nbsp;μL&nbsp;(可选10μL,&nbsp;20μL,&nbsp;50μL)</p><p>大进样体积:满环进样&nbsp;=&nbsp;定量环体积</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;部分进样&nbsp;=&nbsp;1/2定量环体积</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;微升携带进样&nbsp;=&nbsp;(定量环体积&nbsp;-&nbsp;3&nbsp;×&nbsp;针体积)/2</p><p>样品容量&nbsp;:2个标准48位样品瓶&nbsp;(标配)</p><p>进样重复性:满环进样&nbsp;:&nbsp;&nbsp;RSD≤0.3%</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;部分进样&nbsp;:&nbsp;&nbsp;RSD≤0.5%</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;微升携带进样&nbsp;:&nbsp;&nbsp;RSD≤1%</p><p>交叉污染:&lt;0.02%</p><p>线性&nbsp;:0.9999</p><p>大耐压:6,000PSI&nbsp;(可选配15,000PSI进样阀)</p><p>&nbsp;</p><p></p><p>柱温箱</p><p>控温范围:室温+5℃&nbsp;~&nbsp;70℃</p><p>温度准确度:±1.0&nbsp;℃</p><p>温度稳定性:±0.1&nbsp;℃</p><p>柱容量:250&nbsp;mm色谱柱1根及10&nbsp;mm保护柱1根</p><p>&nbsp;</p><p></p><p>紫外-可见检测器</p><p>波长范围:190&nbsp;~&nbsp;800&nbsp;nm</p><p>光源:氘灯,钨灯</p><p>光谱带宽:8&nbsp;nm</p><p>波长准确度:±1&nbsp;nm</p><p>波长精度:&nbsp;0.2&nbsp;nm</p><p>噪声:±0.5×10&nbsp;-5&nbsp;AU&nbsp;(JJG)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;±0.35×10&nbsp;-5&nbsp;AU&nbsp;(ASTM)</p><p>漂移:1×10&nbsp;-4&nbsp;AU/Hr</p><p>线性范围:&gt;5×10&nbsp;4&nbsp;(JJG)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&gt;2.5AU&nbsp;(ASTM)</p><p> 采样率:100&nbsp;Hz</p><p>流通池耐压:1200&nbsp;PSI</p><p>流通池光程:10&nbsp;mm</p><p>流通池体积:12&nbsp;μL</p><p>最小检测浓度:5×10-9&nbsp;g/mL&nbsp;(萘标)</p><p><imgsrc="http://user4.dingdanmao.com/Public/Js/Index/Editor33/attached/20230816/20230816015319_14730.jpg"alt=""/></p><p></p><p>&nbsp;DAD检测器</p><p>二极管阵列:1024像素</p><p>波长范围:190&nbsp;~&nbsp;640&nbsp;nm</p><p>光源:氘灯</p><p>光谱分辨率:0.6&nbsp;nm/像素</p><p>光谱带宽:4.8&nbsp;nm</p><p>波长准确度:±1&nbsp;nm</p><p>波长精度:0.1&nbsp;nm</p><p>噪声:±&nbsp;1.0×10&nbsp;-5&nbsp;AU&nbsp;(JJG)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;±&nbsp;0.6×10&nbsp;-5&nbsp;AU&nbsp;(ASTM)</p><p>漂移:0.5×10&nbsp;-3&nbsp;AU/Hr</p><p>线性范围:&gt;2.0AU&nbsp;(ASTM)</p><p> 采样率:8通道,100&nbsp;Hz;全光谱,100Hz</p><p>流通池耐压:1200&nbsp;PSI</p><p>流通池光程:10&nbsp;mm</p><p>流通池体积:12&nbsp;μL</p><p>小检测浓度:2×10&nbsp;-8&nbsp;g/mL&nbsp;(萘标)</p><p>波长校准:汞灯特征峰和内置氧化钬滤光片</p><p></p><p><imgsrc="http://user4.dingdanmao.com/Public/Js/Index/Editor33/attached/20230816/20230816015329_27941.jpg"alt=""/></p><p>&nbsp;</p>
给我们留言吧
给我们留言 关闭

您好!如需帮助,请留言,我们将尽快联系并解决您的问题